High Flow Oxygen Therapy Breathing Systems

High Flow Oxygen Therapy Breathing Systems deliver optimal humidity and manages excess rain-out.1 Featuring smoothbore inspiratory limbs with embedded heated wires in a reinforced spiral construction.

embedded heated wire breathing system patient

Take back control of humidity

The embedded heated wire throughout the length of the inspiratory tube reduces build-up of rain-out in the circuit compared to conventional heated wire circuits. This provides improved heat distribution in the wall of the breathing circuit, minimises cold spots, maintains gas temperature and humidity levels.

To deliver respiratory gases at optimal temperature and humidity to the patient during High Flow Oxygen Therapy, Flexicare offers our single limb heated wire breathing system in Neonatal, Paediatric and Adult configurations to address the needs of each individual patient, enhancing patient care and improving clinical outcomes.

Reduced Patient Risk

Reduced risk of accidental drainage of rain-out into the patient’s airway.2

Low Compliance Tubing

Accurate delivery of gas volumes and ventilation pressures to the patient.

Temperature Transfer Efficiency

Helps prevent gas temperature loss and surface cold spots, minimising rain-out.

heated wire 038-35-960ek

PARTDESCRIPTIONADDITIONAL COMPONENTSQTYIMAGE
038-35-960EAdult Single Limb Embedded Heated Wire for CPAP / HFOT (1.6m)0.5m Corrugated Limb, Bacterial / Viral Machine Filter and Auto-Fill Chamber10download icon
038-37-960EPaediatric Single Limb Embedded Heated Wire for CPAP / HFOT (1.6m)0.5m Corrugated Limb, Bacterial / Viral Machine Filter and Auto-Fill Chamber10download icon

038-33-402e neonatal heated wire breathing system

PARTDESCRIPTIONADDITIONAL COMPONENTSQTYIMAGE
038-33-402ENeonatal Single Limb Embedded Heated Wire for CPAP / HFOT (1.6m)11F/22F, Pressure Relief Valve 40cmH2O, 22M/22M,15F Connector, 15F/22F Heated Wire Adapter, 2.1m Oxygen Tubing, Auto-Fill Chamber, 0.3m Incubator Extension 15mm, 0.6m Limb 15M10download icon

References

1  MV Pravin Charles, et al. Ventilator-associated pneumonia. Australasian Medical  Journal. 2014; 7(8): 334ñ344.
2  A. R. Wilkes. Heat and moisture exchangers and breathing system filters: their use in anaesthesia and intensive care. Part 2 ñ practical use, including problems, and their use with paediatric patients, Anaesthesia, 2011, 66, 40ñ51.

Reduced Patient Risk

Reduced risk of accidental drainage of rain-out into the patient’s airway.2

Low Compliance Tubing

Accurate delivery of gas volumes and ventilation pressures to the patient.

Temperature Transfer Efficiency

Helps prevent gas temperature loss and surface cold spots, minimising rain-out.

PARTDESCRIPTIONADDITIONAL COMPONENTSQTYIMAGE
038-35-960EAdult Single Limb Embedded Heated Wire for CPAP / HFOT (1.6m)0.5m Corrugated Limb, Bacterial / Viral Machine Filter and Auto-Fill Chamber10download icon
038-37-960EPaediatric Single Limb Embedded Heated Wire for CPAP / HFOT (1.6m)0.5m Corrugated Limb, Bacterial / Viral Machine Filter and Auto-Fill Chamber10download icon
PARTDESCRIPTIONADDITIONAL COMPONENTSQTYIMAGE
038-33-402ENeonatal Single Limb Embedded Heated Wire for CPAP / HFOT (1.6m)11F/22F, Pressure Relief Valve 40cmH2O, 22M/22M,15F Connector, 15F/22F Heated Wire Adapter, 2.1m Oxygen Tubing, Auto-Fill Chamber, 0.3m Incubator Extension 15mm, 0.6m Limb 15M10download icon

CONTACT US

    At Flexicare (Group) Limited we take your privacy seriously and will only use your personal information to manage your account or your enquiry, process your order, to personalise your use of the website, or to post offers of products and services which may be useful to you. We will not share your information for marketing purposes with companies outside of the Flexicare Group. Please refer to our Privacy Statement in full, which can be downloaded here.