VentiMyst®

Flexicare’s Dual Heated Wire Breathing Systems with VentiMyst technology deliver absolute humidity and manages excess rain-out.

VentiMyst®
Heated Wire 
Breathing Systems

VentiMyst Advanced Active Humidification delivers absolute humidity and manages excess rain-out1.

Excessive condensation within a breathing system can cause accidental drainage of rainout into patient’s airway, resulting in Ventilator Acquired Pneumonia (VAP). 

VentiMyst is the ultimate solution for moisture management, actively transferring moisture before it can become hazardous to patients, clinicians and equipment.

Standard Corrugated Heated Wire Limb

With rain-out pooling.

VentiMyst Heated Wire Limb

Reduced build-up of rain-out.

Reduced Risk of Contamination

Closed system and reduction in circuit breaks lowers the risk of contamination reaching the patient, clinician or ventilator.

Reduced Patient Risk

Minimises need to open or break the circuit to remove excess rain-out, therefore decreasing the risk of Ventilator Acquired Pneumonia.2

Reduced Risk of Resistance

Less risk of increased resistance to gas flow from fluid build-up in the expiratory limb or filter.3

Embedded Dual Heated Wire with VentiMyst

Heated wires are embedded in a reinforced spiral construction throughout the length of the smoothbore inspiratory limb, providing improved heat distribution in the wall of the circuit.

Embedded Heated Wire

PARTDESCRIPTIONADDITIONAL COMPONENTSQTY
038-31-304Adult Dual Embedded Heated Wire with VentiMyst (1.6m) - Kit 1Y-Piece with MDI & Pressure Ports, VentiMyst Embedded Heated Wire Expiratory Limb, 0.5m Corrugated Limb, Pressure Line, 22M/22M,15F Connector, 22F/22M Elbow, Auto-Fill Humidification Chamber10

PARTDESCRIPTIONADDITIONAL COMPONENTSQTY
038-31-252Adult VentiMyst Dual Heated Wire (1.6m) - Kit 1Y-Piece with MDI & Pressure Ports, VentiMyst Corrugated Expiratory Limb, 0.5m Corrugated Limb, Pressure Line, 22M/22M, 15F Connector, 22F/22M Elbow, Auto-Fill Chamber10
038-31-253Adult VentiMyst Dual Heated Wire (1.6m) - Kit 2As above without Pressure Line10

PARTDESCRIPTIONADDITIONAL COMPONENTSQTY
038-33-252Neonatal VentiMyst Dual Heated Wire (1.6m) - Kit 1Y-Piece with Suction Port, 0.3m Incubator Extension, VentiMyst Corrugated Expiratory Limb, 8M/8F Ported T-Pieces, 22M/22M, 15F Connector, 8M/15M Connector, Adapter Tube, 22F/22M Elbow, 9-11F/22M,15F Connectors, 10M,8F/15M,11F Connectors, 15F/22F Heated Wire Adapter, Auto-Fill Chamber, Detachable Pressure Line, 0.15m Limb 9-11F/9-11F, 0.6m Limb 22F/22F, 0.6m Limb 15M,11F/22F10
038-33-253Neonatal VentiMyst Dual Heated Wire (1.6m) - Kit 2As above without Auto-Fill Chamber10
038-33-255Neonatal VentiMyst Dual Heated Wire (1.6m) - Kit 3As above with Auto-Fill Chamber for Low Flow10

PARTDESCRIPTIONADDITIONAL COMPONENTSQTY
038-33-252/SNeonatal VentiMyst Dual Heated Wire for SLE Ventilators (1.6m) - Kit 1Y-Piece with Suction Port & Fixed Pressure Line, 0.3m Incubator Extension, VentiMyst Corrugated Expiratory Limb, 8M/8F Ported T-Piece, Red & Amber Flow Restrictors, 22M/22M,15F Connector, 15M-22M/15F Connectors, 22F/22M Elbow, Auto-Fill Chamber, 0.15m Limb 9-11F/9-11F, 0.6m Limb 9-11F/22F, 0.6m Limb 15M,11F/22F10
038-33-253/SNeonatal VentiMyst Dual Heated Wire for SLE Ventilators (1.6m) - Kit 2As above without Auto-Fill Chamber10

References

1  AARC Evidence-based clinical practice guidelines: care of the ventilator circuit and its relation to ventilator-associated pneumonia. Respiratory Care 2003;48(9):869-879.
2  MV Pravin Charles, et al. Ventilator-associated pneumonia. Australasian Medical  Journal. 2014; 7(8): 334ñ344.
3  A. R. Wilkes. Heat and moisture exchangers and breathing system filters: their use in anaesthesia and intensive care. Part 2 ñ practical use, including problems, and their use with paediatric patients, Anaesthesia, 2011, 66, 40ñ51.

Reduced Risk of Contaminationy

Closed system and reduction in circuit breaks lowers the risk of contamination reaching the patient, clinician or ventilator.

Reduced Patient Risk

Minimises need to open or break the circuit to remove excess rain-out, therefore decreasing the risk of Ventilator Acquired Pneumonia.1

Reduced Risk of Resistance

Less risk of increased resistance to gas flow from fluid build-up in the expiratory limb or filter.2

Committed to Clinical Support

Flexicare proudly supports clinicians to enhance their professional development and patient care. We work collaboratively alongside leading specialists to develop products that advance the delivery of their patient’s care.

CONTACT US

    At Flexicare (Group) Limited we take your privacy seriously and will only use your personal information to manage your account or your enquiry, process your order, to personalise your use of the website, or to post offers of products and services which may be useful to you. We will not share your information for marketing purposes with companies outside of the Flexicare Group. Please refer to our Privacy Statement in full, which can be downloaded here.

    If you consent to us using your personal data or contacting you for these reasons please tick to say how you would like us to contact you:

    We use cookies to give you the best experience on our website. By continuing to use Flexicare.com, you give your consent. You can read our Privacy Policy for more information.